Product line RAC Superfocus

High resolution rod anode tubes of product line RAC Superfocus are optimized for digital radiography (DR) applications. These X-ray tubes are recommended for radiographic testing (RT), computed radiography (CR), and digital radiography (DR) in aerospace and energy industry. They feature an internal cooling of target and sealings; fully support the new standard EN ISO 17636-2, provide exchangeable target heads, and a length up to 150 cm at only 70 mm diameter. Additionally, panoramic and directional targets are available.

Product line RAC Superfocus

High resolution rod anode X-ray tube XWT-225-RAC Superfocus

Microfocus X-ray tube XWT-225-RAC Superfocus

Highlights

  • Internal cooling of target and sealings
  • Full support of new standard EN ISO 17636-2
  • Flexible use for film (RT), computed radiography (CR), and digital radiography (DR)
  • Automatic calibration for optimum performance
  • Different target types for high flexibility
  • Easy maintenance with adjusted ready-to-use click-in cathodes and automatic tube venting
  • Unlimited lifetime

Rating

Resolution
Resolution - 3 stars
Power
Power - 5 stars
Magnification
Magnification - 3 stars

Applications

Industries

Non-destructive X-ray inspections in aerospace industry and military

Non-destructive microfocus X-ray inspection in aerospace industry, e.g.:
  • Mechanical components like control valves or flap actuators
  • Circumferential electron beam (EB) welds in conducts and air ducts
  • Rotor blades, turbine blades
  • Aircraft turbines
  • Electronic assemblies
  • (Small) titanium and aluminium castings
  • Composite materials

Non-destructive X-ray inspections in energy industry

Non-destructive microfocus X-ray inspection in energy industry, e.g.: 
  • Wind power stations (power converters, IGCT, IGBT)
  • Pressure valves and pressure vessels (weld seams)
  • Gas turbines (weld seams)
  • Tube-to-tubesheet (TTS) welds of heat exchangers

Technical details for product lines

Service X-RAY WorX Since we are continuously developing our products, the technical data of our products also change regularly. For this reason, we only publish this data in our technical product data sheets. We will be happy to send you technical product data sheets on request. We will also help you to select the most suitable X-ray tube for your application. This email address is being protected from spambots. You need JavaScript enabled to view it..

Scope of delivery

  • Open microfocus X-ray tube with rod anode, target cooling, turbo vacuum pump, vacuum gauge, and electronic drive unit
  • High voltage generator and high voltage cable
  • Prevacuum pump with vacuum hose
  • Cooling unit with hoses and cooling agent
  • Tube controller, power supplies, and safety relays on 19″ mounting panels
  • Set of cables for electrical connection of X-ray tube and components
  • Spare parts case, documentation, and operating software

Options and accessories

  • Exchangeable rod anodes with different target types
  • 19″ rack for controller and power supplies including start button and warning light
  • Control computer
  • Exchangeable tube head with reflection target for up to 350 Watt power

Contact sales departement

Service X-RAY WorX If you are interested in our products or if you need a quote for one of our products, please contact our sales team.